| 8 Channel DSI Gateway Range | ![]() |
|||||
![]() |
![]() |
![]() |
![]() |
|||||||||||||||||
![]() |
||||||||||||||||||||
| L5508DSIP 8 Channel Dimmer for DSI Ballast | £337.77 | £396.88 | ||||||||||||||||||
| L5508DSI 8 Channel Dimmer for DSI Ballast, C-Bus 200mA | £360.32 | £423.38 | ||||||||||||||||||
![]() |
||||||||||||
![]() |
![]() |
|||||||||||
|
Catalogue Number L5508DSI L5508DSIP Line Supply Voltage 220-240VAC Supply Frequency 47-53Hz and 57-63Hz C-Bus Supply Voltage 15-36VDC @ 0mA Load Rating per Channel 200mA (100 ballasts) Minimum Load 15W per channel Control Range 0 - 100% Compatible Loads Tridonic DSI dimmable ballasts or equivalent Channel Output Voltage 0.0 - 0.8V (low) to 11.0 - 13.0V (high) C-Bus Source Current 200mA 0mA Maximum Number of Units on 10 100 a Single C-Bus Network Status Indicators Channel Status (8), Unit and C-Bus Warm Up Time 5 seconds Network Clock Software selectable Network Burden Software selectable C-Bus Termination 2 x RJ45 Socket Load Termination 2 x 1.5mm2 or 1 x 2.5mm2 Operating Temperature Range 0˚C to 45˚C Operating Humidity Range 0 - 95% RH, non-condensing |
|||||||||||
Please click here for a larger image |
||||||||||||
![]() |
||||||||||||
| NEW! Black and White Touch Screen |
||||||||||||
![]() |
||||
![]() |
||||
| The C-Bus 8 channel DSI gateway units are DIN rail mounted units designed to control Atco-Tridonic brand dimmable electronic ballasts featuring the digital serial interface. These DSI units feature learn mode, local and remote overrides for on/off control, channel, C-Bus and unit status indicators. Each DSI channel can drive up to 100 DSI ballasts allowing a total of 800 DSI ballasts to be connected to a single C-Bus/DSI gateway module. The DSI gateway is capable of detecting faulty lamps connected to its terminals and issuing a message onto the C-Bus network. These messages can be read by C-Gate server application, when integrated as part of an overall building management system, lamp status may be reported to a central location. The DSI units are available as passive and current sourcing models that source up to 200mA to the C-Bus network. |
||||||||
![]() |
||||||||
![]() |
||||||||
KEY INPUT UNITS | INPUT UNITS | SYSTEM UNITS | OUTPUT UNITS | WIRELESS | AUDIO | SOFTWARE | DESIGN GUIDEhome | about us | online shop | contact us |
||||
©2008 C-Bus Direct, a division of LDSCo. Reg 5514263Unit 8, Vision House, Kingfisher Business Park Blashford Ringwood Hants BH24 3NX01425 478395designed by eberlin |
||||