![]() |
![]() |
||||
![]() |
|||||
| Single and Two Channel Relay Range | ![]() |
|||||
![]() |
![]() |
![]() |
![]() |
|||||||||||||||||||
![]() |
||||||||||||||||||||||
| 5101R 1 Channel Relay 10A | £121.60 | £142.88 | ||||||||||||||||||||
| 5102RVF 2 Channel Relay 10A | £140.76 | £165.39 | ||||||||||||||||||||
![]() |
![]() |
|||||||||||
![]() |
||||||||||||
| • Programmable via the C-Bus Toolkit Software • Programmed variables are stored in non-volatile memory and are retained in case of loss of mains or C-Bus power • Remote on/off control independent of C-Bus communications • Programmable power up state following power cycling • Logic states (and/or) programmable using the C-Bus Toolkit Software • Panel mounted, small size and volume • RCM (Australia/New Zealand), CE (European Community)compliant |
Catalogue Number 5101R 5102RVF Line Supply Voltage 220-240VAC Supply Frequency 47-53Hz and 57-63Hz C-Bus Supply Voltage 15-36VDC @ 0mA Load Rating per Channel 10A AC3 Contact Type Switched active Voltage free, normally open, non latched Switch Operations Greater than 60,000 operations In-Rush Current 120A (20msec) Compatible Loads Resistive, inductive, incandescent and fluorescent Analog Output 0 - 10VDC, compatible with up to - 2 x 36W immable electronic ballasts C-Bus Source Current 0mA Maximum Number of Units on 100 a Single C-Bus Network Status Indicators C-Bus power available Warm Up Time 5 seconds C-Bus Termination Screw terminals Load Termination Push connectors, 1 x 2.5mm2 Operating Temperature Range 0˚C to 45˚C Operating Humidity Range 0 - 95% RH, non-condensing • Programmable via the C-Bus Toolkit Software |
|||||||||||
Please click here for a larger image |
||||||||||||
![]() |
||||||||||||
| NEW! Black and White Touch Screen |
||||||||||||
![]() |
![]() |
|||
| The C-Bus 1 and 2 channel relay units are panel mounted units suitable for switching resistive, inductive and fluorescent loads. The units are ideally suited for mounting inside fl uorescent lighting products, street lighting columns and adjacent HID luminaires due to their small size and volume. These relay units feature a remote override for on/off control and a C-Bus status indicator. Load control is provided by a special dual contact relay designed for extreme long life with lighting loads, even with power factor corrected fl uorescent lamps. One contact is tungsten designed to withstand high in-rush currents and arcing when opening and the other contact is silver alloy for steady state current operation. The single channel relay also features a 0-10V output, and is compatible with dimmable electronic ballasts, hence the relay may be used to switch line voltage to the ballast as well as dim the output using the 0-10V output. The relay units are available as passive models only, hence do not source current to the C-Bus network. 5102RVF |
||||||||
![]() |
||||||||
![]() |
||||||||
KEY INPUT UNITS | INPUT UNITS | SYSTEM UNITS | OUTPUT UNITS | WIRELESS | AUDIO | SOFTWARE | DESIGN GUIDEhome | about us | online shop | contact us |
||||
©2008 C-Bus Direct, a division of LDSCo. Reg 5514263Unit 8, Vision House, Kingfisher Business Park Blashford Ringwood Hants BH24 3NX01425 478395designed by eberlin |
||||