![]() |
![]() |
![]() |
|||
| Saturn - UK Plate | ![]() |
|||||
![]() |
![]() |
![]() |
![]() |
|||||||||||||||||
![]() |
||||||||||||||||||||
| E5082NLGF 2 Gang Saturn Input Square WHITE | £101.35 | £119.09 | ||||||||||||||||||
| E5082NL380 2 Gang Saturn Input Square CREAM | £101.35 | £119.09 | ||||||||||||||||||
| E5082NL680 2 Gang Saturn Input Square BLACK | £101.35 | £119.09 | ||||||||||||||||||
![]() |
||||||||||||||||
| E5082NL380 2 Gang Saturn Input Square MID-BROWN | £101.35 | £119.09 | ||||||||||||||
| E5084NLGF 4 Gang Saturn Input Square WHITE | £109.22 | £128.33 | ||||||||||||||
| E5084NL380 4 Gang Saturn Input Square CREAM | £109.22 | £128.33 | ||||||||||||||
Please click here for a larger image |
||||||||||||||||
| E5084NL680 4 Gang Saturn Input Square BLACK | £109.22 | £128.33 | ||||||||||||||
![]() |
||||||||||||||||
| E5084NL780 4 Gang Saturn Input Square MID-BROWN | £109.22 | £128.33 | ||||||||||||||
![]() |
![]() |
|||||||
|
C-Bus Supply Voltage 15-36VDC @ 22mA Maximum Number of Units on 50 a Single C-Bus Network Status Indicator Programmable, Dual, Orange and Blue Timer Range 1 sec to 18 hrs Timer Resolution 1 sec Dimmer Control 255 possible levels Mounting Centres 84mm Standard Colours White and Black Operating Temperature Range 0˚C to 45˚C Operating Humidity Range 0 - 95% RH, non-condensing |
|||||||||||
![]() |
||||||||||||
![]() |
||||||||||||
![]() |
||||||||||||
| The British Standard Saturn E5080 Series C-Bus key input units are learn enabled surface switches designed to control lighting and other electrical services connected to a C-Bus network. Suitable for exclusive interiors, the Saturn Series features an impact resistant glass fascia with white, brown, black or cream backing. The round silver fi nish push buttons feature a dual coloured light indicator, providing a visual indication of the switch state. Key input units are fully programmable and may be confi gured as toggle, dimmer, timer or scene control type functions. With C-Bus switches it is possible to realise multi-way, multi-function switching or dimming control. Key input units communicate with all other units and obtain power via a single twisted pair connection to the C-Bus. In the event of C-Bus power failure, non-volatile memory retains all programmed information relating to the unit’s operating status. |
||
KEY INPUT UNITS | INPUT UNITS | SYSTEM UNITS | OUTPUT UNITS | WIRELESS | AUDIO | SOFTWARE | DESIGN GUIDEhome | about us
|
||||
©2008 C-Bus Direct, a division of LDSCo. Reg 5514263Unit 8, Vision House, Kingfisher Business Park Blashford Ringwood Hants BH24 3NX01425 478395designed by eberlin |
||||