| General Input Unit | ![]() |
|||||
![]() |
![]() |
![]() |
![]() |
|||||||||||||||||
![]() |
||||||||||||||||||||
| E5504GI 4 channel general input module | £258.97 | £304.29 | ||||||||||||||||||
![]() |
![]() |
|||
![]() |
||||||||||
|
Catalogue Number E5504GI Supply Voltage 24VAC +/- 10% @ 500mA, power pack not supplied with the unit Supply Frequency 50/60Hz C-Bus Supply Voltage 15-36VDC @ 18mA Auxiliary Output 24VDC @ 250mA Voltage Inputs 0 - 1V, 0 - 5V, 0 - 10V and 0 - 20V Current Inputs 0 - 20mA and 4 - 20mA Impedance Inputs 0 - 500Ω, 0-1kΩ and 0-3kΩ Digital Inputs Yes Broadcast Rate 2 to 1,024 seconds Maximum Number of Units on 10 a Single C-Bus Network Status Indicators Unit and C-Bus A/D Conversion 8 - bit Accuracy 0.5% Warm Up Time 5 seconds Network Clock Software selectable Network Burden Software selectable C-Bus Termination 2 x RJ45 Socket Load Termination 2 x 1.5mm2 or 1 x 2.5mm2 Operating Temperature Range 0˚C to 45˚C Operating Humidity Range 0 - 95% RH, non-condensing |
|||||||||
Please click here for a larger image |
||||||||||
![]() |
||||||||||
| NEW! Black and White Touch Screen |
||||||||||
![]() |
||||||||||
![]() |
||||||||||
| The C-Bus 4 channel general input units are DIN rail mounted units designed to measure digital, voltage, current loop and thermistor inputs and generate messages to the C-Bus network. The unit is designed to broadcast the actual measured value to the C-Bus network, which in turn may be displayed on other C-Bus devices such as the touch screen, C-Gate or C-Lution. In addition, the unit may trigger a group address as a function of the input level, up to eight trigger points may be assigned to a single input channel. The general input unit is designed to interface to third party products, such as light level sensors, temperature sensors, power, frequency, moisture, rate sensors and others. In this way, the general input may be used to extend the functionality of the C-Bus and its ability to integrate with other systems such as HVAC and power monitoring systems. The general input also generates 24VDC to power the external sensors. The general input units are available as passive models only, hence do not source current to the C-Bus network. |
||||||||||
![]() |
||||||||||
![]() |
||
©2008 C-Bus Direct, a division of LDSCo. Reg 5514263Unit 8, Vision House, Kingfisher Business Park Blashford Ringwood Hants BH24 3NX01425 478395designed by eberlin |
||||
KEY INPUT UNITS | INPUT UNITS | SYSTEM UNITS | OUTPUT UNITS | WIRELESS | AUDIO | SOFTWARE | DESIGN GUIDEhome | about us | online shop | contact us |
||||